03DelcoRemy Diagnostic Manual130004222020
03DelcoRemy Diagnostic Manual130004222020 Diagnostic Procedures Manual For Starters and Alternators Made with FlippingBook RkJQdWJsaXNoZXIy MTEyNjY3NA== 03DelcoRemy Diagnostic Manual130004222020 Table of Contents I ) Introduction and Description 1â1. Introduction 1 1â7. Description 1 1â12. Electrical Fundamentals 2 II ) Diagnosis Charts 2â1. Overcharge Symptoms 8 2â2. Undercharge Symptoms 9 2â3. Milled Pinion Symptoms 10 III ) Testing 3â1. Testing Freedom Batteries 11 3â4. Testing Conventional Batteries 11 3â5. Test Procedure 12 3â7. Battery Cable Test with Single-Battery Location 12 3â10. Battery Cable Test with Dual-Battery Locations 14 3â13. Starter Solenoid Circuit Test 14 3â18. Magnetic Switch Circuit Test 16 3â21. Starter Replacement Determination 17 3â26. Alternator Wiring Test 18 3â29. Alternator Replacement Determination 19 3â33. Completion of All Tests 20 IV ) Summary V ) Appendix 5â1. Smart IMS or SIMS Diagnostic Steps 22 5-2. Overcrank Protection (OCP) Circuit Check 23 5-3. Multi-Battery Charging with Series and Parallel Chargers 23 5-4. Group Charging on Current-Limiting or Series Chargers 24 5-5. Group Charging on Voltage-Limiting or Parallel Chargers 24 5-6. Heavy Duty Diagnostics Procedures Data 25 Section Page Made with FlippingBook RkJQdWJsaXNoZXIy MTEyNjY3NA== 03DelcoRemy Diagnostic Manual130004222020 delcoremy.com Page 1 1-1. INTRODUCTION 1-2. PURPOSE. This manual provides diagnostic procedures that can be used for troubleshooting a heavy duty electrical system, including the starting and charging systems. Some procedures also may be used for preventative maintenance checks. These procedures are applicable to systems using heavy duty starters such as: Delco Remy 28MTâ¢, 29MT TM , 31MTâ¢, 35MT TM , 37MT TM , 38MT TM , 39MT TM , 41MT TM , 42MT TM , 50MT TM or a similar starter with adequate battery power for the engine/starter application used. 1-3. DEFINITION OF DIAGNOSIS. Diagnosis is the three-part process that begins when a problem is perceived and ends when the equipment is confirmed as serviceable. Three questions must be answered to assure completion: 1. What are the symptoms? This is what has been observed (seen, heard, felt or smelled), indicating a problem. 2. What caused the symptoms? Diagnostic procedures are used to identify the root cause of the problem. 3. How do we fix it? Usually this involves the adjustment, repair or replacement of some part or parts. 1-4. This manual defines the procedures to determine the cause of the symptoms. Actual adjustment, repair and replacement procedures are provided in unit-specific service bulletins and manuals. 1-5. For educational purposes, study of this entire manual is recommended. For diagnostic purposes, the flow charts in Section II will reference appropriate procedures for specific symptoms. 1-6. EQUIPMENT REQUIRED. To perform the tests specified in this manual, the following equipment is required: 1. A variable carbon pile load tester with more than 500 amps capacity with ammeter (and voltmeter). 2. A separate DC voltmeter, digital preferred, capable of reading 0.01 volt increments. 3. An inductive (clamp-on) ammeter for safe and accurate current measurements. 4. A hand held or bench top type tester. 1-7. DESCRIPTION 1-8. SYSTEM. The heavy duty electrical system is comprised of the starting and charging systems. These systems are, in turn, comprised of batteries, the starter, the alternator, and the interconnecting wiring and electrical and mechanical switches. For maximum operating efficiency, all parts of the system must be functioning properly. S E C T I O N 1 Introduction and Description FIGURE 1-1. Heavy Duty Electrical System 1. Battery 2. Starter 3. Alternator 4. Magnetic Switch 5. Push Button Switch 6. Key Switch Made with FlippingBook RkJQdWJsaXNoZXIy MTEyNjY3NA== 03DelcoRemy Diagnostic Manual130004222020 Page 2 1-9. BATTERIES. Batteries are perishable devices that wear out at some point in time. With use, they deteriorate and eventually become incapable of performing their important job. In addition, new batteries may become discharged for various reasons. Neither worn out nor discharged batteries can supply the power necessary for cranking. Thus, the battery check becomes the starting point for diagnosing electrical system problems. 1-10. SUBCIRCUITS. Because of vibration, corrosion, temperature changes or damage, the performance of wiring, connections and secondary components as well as the function of the starter and alternator can deteriorate. This, in turn, can cause malfunctions within the starting and charging systems. For the purpose of testing, wiring and components are divided into four circuits that must be tested. These are: 1. Cranking Circuit. This consists of the large cables that carry the high starter current. Excessive loss here causes slow cranking speeds, especially in cold weather. Inability to start from slow cranking can lead to starter damage if the starter is cranked over 30 seconds. Deeply discharged or worn-out batteries also can cause the same problem. 2. Solenoid Circuit. This consists of the wiring from the battery, through a push button or magnetic switch, to the S terminal of the starter solenoid, and back to the battery. Excessive loss here can cause the solenoid to shift in and out (chatter), resulting in a no-start condition. This can cause a damaged contact disc and terminals of the starter solenoid. Deeply discharged batteries also can cause this problem. 3. Magnetic Switch Circuit or IMS (when the magnetic switch is used). This consists of the wiring from the battery, through a key switch and/or start button, to the coil of the magnetic switch, and back to the battery. Excessive loss here can cause a âno startâ complaint. 4. Charging Circuit. This consists of the wiring between the alternator and the battery and back to the alternator. Excessive loss here can cause the batteries to not charge properly. As noted above, discharged batteries will cause other problems. 1-11. SEQUENCE OF PROCEDURES. It is important that these procedures be followed in the exact sequence specified. Batteries, wiring and connections should be checked and corrected to the specifications given. If cranking problems still occur, then connecting cables should be checked before replacing the starter with a known good unit. Similarly, in the charging circuit, the batteries, wiring and connections should be thoroughly checked and corrected to the specifications given. Only then should the alternator be checked and replaced if necessary. 1-12. ELECTRICAL FUNDAMENTALS 1-13. TERMS AND DEFINITIONS. The following are electrical terms and definitions used in this manual: 1. Voltage. Voltage is the electrical pressure or force that causes current or electrons to flow through a conductor. The voltage also can be described as the difference in electrical pressure between two points in a circuit. This electrical force or pressure is measured in volts. 2. Current. Electrical current is the flow or movement of electrons in a conductor. This movement can be compared to the flow of water through a pipe. Without pressure (voltage), the current will not flow. Electrical flow is measured in amperes, most often abbreviated as amps. 3. Resistance. Resistance is the opposition to current flow. For a given electrical pressure (voltage), resistance decreases current flow. This can be detected by voltage loss or drops in the electrical circuit. Electrical resistance is measured in ohms. 4. Magnetic Field.When electrical current flows through a conductor, a magnetic field is produced around the conductor. By measuring the strength of this magnetic field, it is possible to determine the amount of the current flow or amperage. This principle is the basis for the function of the clamp-on or induction type ammeter. 1-14. MEASURING VOLTAGE WITH THE VOLTMETER. The voltmeter is used to measure electrical pressure or voltage. The unit of measure is the volt. Voltmeters are always connected across (in parallel with) a part of the electrical circuit (See Figures 1-6 and 1-7). The voltmeter measures the difference in electrical potential or pressure between the points where the voltmeter is attached. 1-15. VOLTMETER SELECTION. Voltmeters for the purposes described in this manual are DC instruments with a range as follows: 1. Low scale: 0-3 volts 2. 12-volt vehicles: 0-16volts 3. 24-volt vehicles: 0-32volts MAGNETIC FIELD CURRENT DP-1005 Made with FlippingBook RkJQdWJsaXNoZXIy MTEyNjY3NA== 03DelcoRemy Diagnostic Manual130004222020 delcoremy.com Page 3 NOTE The use of digital voltmeters is highly recommended for the following reasons: ⢠Digital voltmeters are generally more accurate than analog (needle movement) instruments. ⢠Digital readings need no interpretation; everyone sees the same number. ⢠Digital instruments are generally auto ranging; they automatically select the proper range for the value of the reading. ⢠Reversing polarity with a digital instrument will simply result in a negative reading (minus sign) whereas with an analog voltmeter, reversing polarity could damage the meter. ⢠If analog meters are not read directly facing the meter, inaccuracies may result. 1-16. VOLTMETER USE. Figures 1-6 through 1-8 illustrate the proper use of the voltmeter and the types of readings that can be expected. 1. Figure 1-1 shows the voltmeter being used with no current flow or with the starter not operating. FIGURE 1-1. Voltmeter Readings with No Current Flow FIGURE 1-2. Voltmeter Readings with Current Flow NOTE When the voltmeter is connected parallel to a cable (meter leads and cable ends start and end at the same point), the meter will measure the voltage potential at both ends of the cable. Without current flowing, the values always will be the same and the voltmeter will read zero. 2. Figure 1-2 shows the voltmeter being used with current flow (starter pulling 500 amps). NOTE The V1 reading (See Figure 1-2) means that with 500 amps flowing through the positive cable, there is a 1.0 volt drop in that cable. There must be current flow in order to produce a voltage drop. The V2 reading (See Figure 1-2) of 0.3 volt means that with 500 amps flowing through the negative cable, there is a 0.3 volt drop in the negative cable. 3. Figure 1-3 illustrates the digital voltmeter reading in a DC system with both correct and incorrect polarity. Whenever the minus sign is displayed, the meter leads must be reversed to obtain the correct polarity. 0 V DP-1006 0 V O V V4 12.5V 0 V V3 0V 12.5 V 12.5V V2 12.5 V V1 0 V 0 V 12.5 V 12.5 V DP-1007 0.3 V 0.3 V V2 8.5 V V1 1.0 V 7.5 V 8.5 V V2 7.2 V 0.3 V V1 0 V 8.5 V 7.5 V Made with FlippingBook RkJQdWJsaXNoZXIy MTEyNjY3NA== 03DelcoRemy Diagnostic Manual130004222020 Page 4 DIGITAL VOLTMETER CONNECTED CORRECTLY IN RELATIONSHIP TO POLARITY DIGITAL VOLTMETER CONNECTED INCORRECTLY IN RELATIONSHIP TO POLARITY (VALUE CORRECT BUT MINUS SIGN WILL SHOW TO ALERT OPERATOR THAT LEADS ARE REVERSED) DP-1008 12.5 V1 -12.5 V1 FIGURE 1-3. Correct and Incorrect Polarity Readings 1-17. MEASURING CURRENT FLOWWITH THE AMMETER. The ammeter is used to measure current flow. The unit of measure is the ampere or amp. Unless the induction pickup (clamp-on) ammeter is used, the circuit must be opened and the ammeter connected in series in order to take measurements. 1-18. AMMETER SELECTION. With but a few exceptions (See Figure 1-10), it is desirable to make ammeter readings without opening up the circuit and thus disturbing a circuit defect and preventing it from being discovered. Therefore, the use of a clamp-on induction-type ammeter is recommended for most of the measurements described in this manual. This type is easy to use, cannot be damaged by misconnection, and will not damage the vehicle wiring. A clamp-on ammeter operates by measuring the magnetic flux produced by current flow through a conductor and translating that into amperes, which are displayed on the meter readout. 1-19. AMMETER USE. Figures 1-4 through 1-6 illustrate the use of various types of ammeters. 1. Figure 1-4 illustrates the use of an in-line digital ammeter. Note that the circuit must be disconnected in order to use this type of meter. The type of unit shown is an internal shunt and generally used for loads of 10 amps or less. Care must be taken to not measure current greater than the meter rating. This type of ammeter is not recommended for most of the measurements described in this manual. However, if this is the only type available, be sure to follow the meter manufacturerâs instructions for connection and use. FIGURE 1-4. In-Line Digital Ammeter 2. Figure 1-5 shows an in-line digital ammeter used to measure an unknown current draw. An example of this might be the result of a parasitic load. On the 10 amp scale, the current would be too low to be measurable. However, with the meter on the 300 mA scale, the current draw in milliamps can be read. FIGURE 1-5. In-Line Ammeter 3. Figure 1-6 shows a clamp-on ammeter, the most common type of current measurement described in this manual. Zero out the meter before using and make sure the jaws are completely closed during use. Place the meter jaws around the cable, with the arrow points in the direction of current flow, to measure all the current. 10A 10 AMPS OR LESS LOAD DP-1009 UNKNOWN CURRENT DRAW DP-1010 Made with FlippingBook RkJQdWJsaXNoZXIy MTEyNjY3NA== 03DelcoRemy Diagnostic Manual130004222020 delcoremy.com Page 5 CLAMP-ON TYPE AMMETER DP-1011 FIGURE 1-6. Clamp-On Type Ammeter 1-20. MEASURING RESISTANCE WITH THE OHMMETER. The ohmmeter is used to measure electrical resistance. The unit of measure is the ohm. The ohmmeter is connected across the unit or portion of the circuit for which the resistance is to be measured. The ohmmeter has its own power source, usually a small battery, which causes current to flow through the circuit to be measured. Since the meter power source (battery) voltage is known, the current is inversely proportional to the resistance of the circuit. The meter automatically computes and reads out the resistance: E (voltage) divided by I (current) equals R (resistance). 1-21. OHMMETER SELECTION. As with voltmeters and ammeters, both analog (needle) and digital ohmmeters are available. Digital ohmmeters are preferred for the same reasons as the others. Additionally, most digital ohmmeters have a diode scale which can be used to test diodes and transistors. 1-22. OHMMETER USE. Figures 1-7 through 1-9 illustrate some typical uses of the ohmmeter. CAUTION Typical heavy duty electrical system voltage (12 or 24-volts) could produce a current flow through the ohmmeter that could damage the meter. Never connect an ohmmeter to a circuit that is under voltage. Always disconnect the battery ground cable before using the ohmmeter. 1-23. As shown in Figures 1-7 and 1-8, the ohmmeter also is useful as a continuity meter. An infinite ohmmeter reading (See Figure 1-7) indicates an open circuit (no continuity). A very low (approaching zero) reading (See Figure 1-8) indicates continuity. Figure 1-9 illustrates some digital ohmmeter applications. FIGURE 1-7. Analog Ohmmeter Showing Open Circuit NOTE Most digital meters have a diode scale ( ) which must be used to check diodes or transistors rather than the ohm scale. 1-24. APPLYING AN ELECTRICAL LOAD WITH A CARBON PILE. (See Figure 1-10) The carbon pile is a variable resistor designed to carry high current. A carbon pile, along with a voltmeter and ammeter, is normally an integral part of a modern battery tester. In addition to load testing batteries, carbon piles are used to test starter and alternator circuits. FIGURE 1-8. Analog Ohmmeter Showing Continuity TOUCHING GROUND OHMMETER OPEN OHMETER DP-1012 TRUCK FRAME DP-1013 Made with FlippingBook RkJQdWJsaXNoZXIy MTEyNjY3NA== 03DelcoRemy Diagnostic Manual130004222020 Page 6 EXAMPLES DP-1014 .450 2.3 0.00 COIL DIODE DIGITAL DIGITAL OL FIGURE 1-9. Digital Ohmmeter CAUTION On 24-volt systems, use only a carbon pile specifically designed for 24-volt use. A 12-volt carbon pile could be damaged if used in a 24-volt circuit. 1-25. THE BASIC HEAVY-DUTY ELECTRICAL SYSTEM. Todayâs basic heavy duty electrical system (See Figure 1-1) consists of batteries (usually three or four, but up to eight connected), a starter, an alternator, a magnetic switch, an ignition switch, a push-button switch, and the required wiring. The batteries provide the high current required by the starter. The magnetic switch controls the battery current to the starter solenoid. The ignition and push-button switches activate the magnetic switch, which in turn energizes the starter. If all functions work properly, the engine will crank. 1-26. The mechanical energy of the running engine provides the power for the alternator. The alternator creates the electrical energy needed to recharge the batteries and power the vehicleâs electrical accessories and loads. DP-1015 FIGURE 1-10. Carbon Pile 1-27 . How well the electrical system components are matched will determine in a large part how effectively and efficiently the system will operate. Another important factor in system design is that system wiring must be adequate to carry the current required by each circuit. 1-28. HEAVY DUTY SYSTEM BATTERIES. The battery, or batteries, in the heavy duty electrical system are devices for storing energy. They convert chemical energy into the electrical energy needed to operate the starter. With the engine running, the alternator supplies electrical energy to the batteries, which they convert into chemical energy and store for later use. Made with FlippingBook RkJQdWJsaXNoZXIy MTEyNjY3NA== 03DelcoRemy Diagnostic Manual130004222020 delcoremy.com Page 7 There are three types of lead acid batteries used in commercial vehicle applications today: the maintenance-free flooded electrolyte battery, the AGM battery, and the Thin Plate Pure Lead (TPPL) AGM battery. Unlike maintenance-free, flooded, lead acid batteries that have liquid electrolyte, an AGM battery contains a glass mat separator made of fiberglass that is placed between each plate to absorb the electrolyte. Fleets should prevent batteries from becoming deeply dischargedâdropping to less than 10 volts due to extended storage with vehicle support loads. Also, trying to start trucks with a low state of charge or weak capacity batteries can cause high amperages and low voltages. This can overheat the starter motor and damage battery cables. A voltmeter on the battery terminals will indicate the batteryâs State of Charge (SOC). State of Charge Flooded Battery AGM Battery TPPL AGM Battery 100% 12.70+ 12.80+ 12.84+ 75% 12.40 12.60 12.50 50% 12.20 12.30 12.20 25% 12.00 12.00 11.90 0% 11.80 11.80 11.50 Made with FlippingBook RkJQdWJsaXNoZXIy MTEyNjY3NA== 03DelcoRemy Diagnostic Manual130004222020 Page 8 PRELIMINARY DIAGNOSIS FLOW CHART 2-1. OVERCHARGE SYMPTOMS ⢠High voltmeter readings ⢠Battery smells bad ⢠Battery spews acid or smells ⢠Bright or burned out lights INTERNAL VOLTMETER REPLACE ALTERNATOR RUN ENGINE APPROX 2000RPM CHECK VOLTS ATALTERNATOR EXTERNAL REGULATOR USE REG. SVC. BULLETIN TO ISOLATE DEFECT VERIFY COMPLAINT REPAIR VOLTMETER RETEST WITH COOL, CHARGED BATTERIES REPLACE DEFECTIVE BATTERY COMPLETE CHECK DASH VOLTMETER CHECK BATTERY TEMPERATURE TEST BATTERIES (PAGE 3-1) COMPLETE 119 Ë F OR LESS 120 Ë F OR MORE DEFECTIVE LESS THAN 15.5 V DEFECTIVE OK OK MORE THAN 15.5 V S E C T I O N I I Diagnosis Flow Charts Made with FlippingBook RkJQdWJsaXNoZXIy MTEyNjY3NA== 03DelcoRemy Diagnostic Manual130004222020 delcoremy.com Page 9 PRELIMINARY DIAGNOSIS FLOW CHART 2-2. UNDERCHARGE SYMPTOMS ⢠Slow or no cranking ⢠Low voltmeter reading ⢠Dim lights/slow turn signal flashers START VEHICLE CHECK ALTERNATOR VOLTAGE & OUTPUT (PAGE 19) TIGHTEN BELT TO MANUFACTURER TENSION SPECS CHECK STARTER SOLENOID CIRCUIT (PAGE 14) REPAIR WIRING CIRCUIT - VERIFY REPAIR CHECK DRIVE BELT VERIFY COMPLAINT TEST BATTERIES (PAGE 11) CHECK CRANKING CIRCUIT (PAGE 12) REPAIR AND VERIFY REPAIR SEE STARTER REPLACEMENT DETERMINATION (PAGE 17) CHECK PULLEYS FOR LOCKED BEARINGS REPAIR DEFECTIVE COMPONENT REPLACE BELT CHARGE BATTERIES CRANK ENGINE CHECK ALTERNATOR VOLTAGE & OUTPUT (PAGE 19) SLOW OK OK OK LOCKED DEFECTIVE OK OK OK DEFECTIVE OK OK BUT DISCHARGED MISSING LOOSE Made with FlippingBook RkJQdWJsaXNoZXIy MTEyNjY3NA== 03DelcoRemy Diagnostic Manual130004222020 Page 10 PRELIMINARY DIAGNOSIS FLOW CHART 2-3. MILLED PINION SYMPTOMS ⢠Starter spins / no-crank ⢠Click / no-crank (may be intermittent) VERIFY COMPLAINT VISUALLY CHECK RING GEAR CHECK STARTER PER APPROPRIATE SERVICE BULLETIN REINSTALL STARTER AND PERFORM CIRCUIT CHECKS (SEE PAGE 3-4) REMOVE STARTER â VISUALLY CHECK PINION CHECK AND REPAIR SOLENOID CIRCUIT REPAIR VERIFIED REPAIR OR REPLACE STARTER (DO NOT INSTALL) REPLACE RING GEAR AND CHECK FLANGE TO FLYWHEEL DIM REPLACE STARTER AND VERIFY REPAIR CONNECT VOLTMETER FROM SOLENOID âSâ TERMINAL TO GROUND â ENGAGE START SWITCH DEFECTIVE OK MILLED TEETH OK OK OK SYMPTOMS CONTINUE MILLED PINION MORE THAN 6.0 V NO VOLTS Made with FlippingBook RkJQdWJsaXNoZXIy MTEyNjY3NA== 03DelcoRemy Diagnostic Manual130004222020 delcoremy.com Page 11 3-1. TESTING FLOODED LEAD ACID MAINTENANCE FREE BATTERIES WITH A HYDROMETER EYE CAUTION When handling batteries, wear face or eye protection and provide good ventilation. Have a water supply available, and keep away from fire, flame or sparks. 3-2. TEST PROCEDURE. Disconnect NOTE If battery has threaded terminals, use terminal adapters or verify you are testing on the lead pads not the threaded terminals. Testing using the studs can create a false bad battery reading. NOTE If you are using an hand held electronic tester, then follow the instructions provide with the tester. Inspect 1. Each battery visually for damage. 2. Battery hydrometer eye. ⢠If battery has no hydrometer eye, proceed to step 3. ⢠Eye shows green, proceed to step 3. ⢠Eye shows dark, recharge battery, then proceed to step 3. ⢠Eye shows yellow, replace battery. 3. Apply 300 amp load to battery for 15 seconds and turn off load. Wait one minute. 4. If battery has no hydrometer eye, measure terminal voltage: Test a. If 12.4 volts or more, continue test. b. If less than 12.4 volts, recharge battery, and repeat steps 3 and 4. Test 5. All batteries passing previous inspection or test as follows: a. Apply test load of 1\2 CCA rating at 0ËF in amps. b. After 15 seconds with load on, measure and record battery terminal voltage. c. Turn load off. d. Estimate battery temperature and check recorded voltage against following table. Temp. 0F 70 50 30 15 0 Min. Volts 9.6 9.4 9.1 8.8 8.5 e. If recorded voltage does not meet or exceed that in table, replace battery. Otherwise, battery is okay. 3-3. TEST COMPLETION. Clean 1. Cable ends and battery terminals with wire brush. Tighten 1. Battery hold-downs to specifications. NOTE Leave battery cables disconnected and proceed with wiring tests. ST1201 ADAPTER PRIMARY BATTERY CONNECTION AREA STUD TERMINAL DP-1019 FIGURE 3-1. Testing Batteries 3-4. TESTING BATTERIES CAUTION When handling batteries, wear face or eye protection and provide good ventilation. Have a water supply available, and keep away from fire, flame or sparks. S E C T I O N I I I Diagnostic Testing Made with FlippingBook RkJQdWJsaXNoZXIy MTEyNjY3NA== 03DelcoRemy Diagnostic Manual130004222020 Page 12 3-5. TEST PROCEDURE Disconnect NOTE If battery has threaded terminals, use terminal adapters or verify you are testing on the lead pads not the threaded terminals. Testing using the studs can create a false bad battery reading. NOTE If you are using an hand held electronic tester, then follow the instructions provide with the tester. Inspect 1. Each battery visually for damage. 2. Electrolyte level. ⢠If fluid is above top of plates in all cells, proceed to step 3. ⢠If fluid is not above top of all plates, add water as required and charge battery for 15 minutes at 15-25 amps to mix electrolyte. Then proceed to step 3. 3. Electrolyte specific gravity with hydrometer at 80Ë F. Readings for all cells should not be less than 1.230. The difference between high and low reading should not exceed 0.050. ⢠If battery meets above requirements, proceed to next test. ⢠If readings show a difference of more than 0.050, replace the battery. ⢠If readings show less than 0.050 difference but one or more cells read less than 1.230, recharge the battery. Remove 1. All battery caps. Test 2. Apply 300 amp load to battery for 15 seconds and turn off load. 3. If blue haze is seen in any cell, replace battery. Otherwise, proceed with next test. Test 1. All batteries passing previous inspections or tests as follows: a. Measure and record electrolyte temperature and replace vent caps. b. Apply test load of 1\2 CCA rating at 0ËF in amps. c. After 15 seconds with load on, measure and record battery terminal voltage. d. Turn load off. e. Check recorded voltage against following table for electrolyte temperature. Temp. 0F 70 60 50 40 30 20 10 0 Min. Volts 9.6 9.5 9.4 9.3 9.1 8.9 8.7 8.5 f. If recorded voltage does not meet or exceed that in table, replace battery. Otherwise, battery is okay. 3-6. TEST COMPLETION. Clean 1. Cable ends and battery terminals with wire brush. Tighten 1. Battery hold-downs to specifications. NOTE Leave battery cables disconnected and proceed with wiring tests. FIGURE 3-2. Testing Batteries 3-7. BATTERY CABLE TEST WITH SINGLE BATTERY LOCATION (SEE FIGURE 3-3) CAUTION If the vehicle has a combination 12/24-volt system using a series- parallel switch or a T/R alternator, do not use this procedure. Contact BorgWarner Technical Support at 800-372-0222 or email drts@borgwarner.com for information on such systems. Made with FlippingBook RkJQdWJsaXNoZXIy MTEyNjY3NA== 03DelcoRemy Diagnostic Manual130004222020 delcoremy.com Page 13 Slow or sluggish cranking may be caused by high resistance in the battery cables or connections, especially in cold weather. After all batteries test well and the terminals are clean, check the battery cables. This involves placing an adjustable carbon pile load on the batteries at the starter and then measuring the voltage drop in each cable. The voltage drop in the positive cable plus the voltage drop in the negative cable equals the total drop or the difference between the battery voltage and the starter voltage. 3-8. TEST PROCEDURE. NOTE For a 24-volt system, use a 24-volt carbon pile. As an alternative, connect only one 12-volt battery to the system (disconnect all other batteries). Test at 12-volts but use the amperage specified for a 24-volt system. Immediately upon completion of tests, reconnect batteries in the approved manner for a 24-volt system. Connect CAUTION Starter solenoid BAT terminal is at battery voltage when batteries are connected. 1. Positive carbon pile lead to starter solenoid BAT terminal. 2. Negative carbon pile lead to starter ground terminal. 3. Battery cables (see NOTICE above) if not already connected. NOTE At starter, make voltmeter connection to terminalânot to carbon pile clamp. 4. Low scale digital voltmeter from starter solenoid BAT terminal to battery positive. Test 1. Turn on carbon pile and adjust load to 500 amps (250 amps for 24-volt system). 2. Read and record positive cable voltage drop (V4), then turn off carbon pile. Connect NOTE At starter, make voltmeter connection to terminalânot to carbon pile clamp. 1. Low scale digital voltmeter from starter ground terminal to battery negative. Test 1. Turn on carbon pile and adjust load to 500 amps (250 amps for 24-volt system). 2. Read and record negative cable voltage drop, (V5) then turn off carbon pile. 3. Add positive cable loss (V4) and negative cable loss (V5) to get total cable loss (V3). This loss (V3) shall not exceed: ⢠12-volt system with 37MT, 40MT, 41MT or 42MT starter â 0.500 volt maximum voltage loss ⢠12-volt system with 50MT starter â 0.400 volt maximum loss ⢠24-volt system with 37MT, 40MT, 41MT, 42 MT, or 50 MT starter â 1.000 volt 4. Replace cables or repair circuits with excessive voltage drop. 3-9. TEST COMPLETION. If temporary 12-volt test connections were made for 24-volt systems, reconnect batteries to vehicle specifications for 24-volt operation before starting vehicle. However, if the tests following are to be performed, keep the temporary 12-volt hook-up. FIGURE 3-3. Battery Cable Test â Typical 12-Volt System Made with FlippingBook RkJQdWJsaXNoZXIy MTEyNjY3NA== 03DelcoRemy Diagnostic Manual130004222020 Page 14 3-10. BATTERY CABLE TEST WITH DUAL-BATTERY LOCATIONS (SEE FIGURE 3-4) This test applies if the vehicle has more than one battery location and the batteries are connected to the starter by separate cables. Essentially, this is the same as the previous test with a single battery location (paragraphs 3-7 through 3-9) except as follows: 3-11. TEST PROCEDURE (See Figure 3-4). NOTE If the system usually operates on 24-volts, connect one battery at each location to the starting motor, making a temporary 12- volt system. 1. Disconnect batteries from first set. 2. Test second set cables as described in paragraph 3-8 except apply 250 amp load at starter (125 amp for 24-volt system). 3. Use same voltage drop or loss limits as specified in paragraph 3-8. 4. Reconnect first set of batteries and disconnect second set. 5. Repeat steps 2 and 3 for first set of cables. 6. Replace cables or repair circuits with excessive voltage drop. 3-12. TEST COMPLETION. If temporary 12-volt test connections were made for 24-volt system, reconnect batteries to vehicle specifications for 24-volt operation before starting vehicle. However, if the tests following are to be performed, keep the temporary 12-volt hook-up. CARBON PILE POSITIVE VOLTAGE LOSS NEGATIVE VOLTAGE LOSS FIRST SET SECOND SET FIGURE 3-4. Battery Cable Test - Typical Dual Box 12-Volt System 3-13. STARTER SOLENOID CIRCUIT TEST The starter shifting in and out, or not pulling in, is often caused by high resistance in the starter solenoid circuit. When the solenoid circuit has excessive voltage loss, the starter pinion may not engage the flywheel. If it does engage, it may drop out too soon when battery voltage lowers. The solenoid circuit usually consists of a magnetic switch with leads to and from the starter solenoid. Some vehicles use only a push-button switch to control the starter solenoid and this same test applies. Made with FlippingBook RkJQdWJsaXNoZXIy MTEyNjY3NA== 03DelcoRemy Diagnostic Manual130004222020 delcoremy.com Page 15 NOTE For starters with an integral magnetic switch, use the test procedures specific to those starters. NOTE When testing 24-volt systems, use the same temporary 12-volt connection as for the Battery Cable Test, paragraph 3-7. 3-14. SOLENOID CIRCUIT VOLTAGE LOSS TEST (See Figure 3-5). Disconnect 1. Lead to S terminal on starter solenoid. Connect 1. Carbon pile to switch wire lead and to starter ground terminal (a small clamp or jumper wire may be helpful). 2. Positive lead of digital voltmeter set on low scale to solenoid BAT terminal. 3. Negative lead of voltmeter to switch wire lead to which carbon pile is connected. Meter will show battery voltage. NOTE In the following step, if the magnetic switch does not close on a 12-volt vehicle, perform Magnetic Switch Circuit Test, paragraph 3-18, then return to this point in the Starter Solenoid Circuit Test. NOTE In the following step on a 24-volt vehicle, if the temporary 12-volt system will not close the magnetic switch, bypass it with a heavy jumper connected between the two large studs on the magnetic switch. Electrically this does the same thing as pushing the button and closing the switch. With no button to release, the jumper must be disconnected after each voltage reading. Test 1. Have assistant push starter button with key on. Listen for sound of magnetic switch closing. Voltmeter reading should be zero. 2. Turn on and adjust carbon pile to 100 amp load (60 amp if 24- volt system). 3. Read and record voltage (V6) onvoltmeter. 4. Voltage loss shall not exceed: 12-volt system - 1.0 volt 24-volt system - 2.0 volt 5. If circuit voltage loss is less than maximum, solenoid circuit is okay, turn off and disconnect carbon pile and proceed to Magnetic Switch Circuit Test, paragraph 3-18. If voltage loss exceeds maximum, loss is excessive. This may be caused by loose terminals, corrosion, too small a wire, switch located too far from starter, or worn out magnetic switch. Perform Wiring Test, paragraph 3-15, and Magnetic Switch Contactor Test, paragraph 3-16, to isolate the problem. VOLTAGE (6) CARBON PILE FIGURE 3-5. Starter Solenoid Circuit Test 3-15. WIRING TEST (See Figure 3-6). With carbon pile connected as instructed in previous Starter Solenoid Circuit Test, proceed as follows: Connect 1. Plus lead of digital voltmeter set on low scale to solenoid BAT terminal. 2. Minus lead of voltmeter to a large terminal on magnetic switch. If voltage shows, reconnect lead to other large terminal on magnetic switch. NOTE In the following step, on a 24-volt vehicle, if the temporary 12-volt system will not close the magnetic switch, bypass it with a heavy jumper connected between the two large studs on the magnetic switch. Electrically this does the same thing as pushing the button and closing the switch. With no button to release, the jumper must be disconnected after each voltage reading. Made with FlippingBook RkJQdWJsaXNoZXIy MTEyNjY3NA== 03DelcoRemy Diagnostic Manual130004222020 Page 16 Test 1. Push starter button with key on. 2. Turn on and adjust carbon pile to 100 amp load (60 amp if 24-volt system). 3. Read and record voltage (V9) onvoltmeter. Connect 1. Positive lead of digital voltmeter set on low scale to switch wire lead to which carbon pile is connected. 2. Negative lead of voltmeter to other large terminal on magnetic switch. Test 1. Push starter button with key on. 2. Turn on and adjust carbon pile to 100 amp load (60 amp if 24-volt system). 3. Read and record voltage (V10) on voltmeter. 4. Add voltage loss (V10) to voltage loss (V9), previously recorded, to get total wire voltage loss. 5. Total wire voltage loss shall not exceed: 12-volt system - 0.8 volt 24-volt system - 1.8 volt 6. Replace and repair wiring and connections if voltage loss is excessive. NOTE Perform the following test only if the magnetic switch closed in preceding tests. 3-16. MAGNETIC SWITCH CONTACTOR TEST (See Figure 3-6). With carbon pile connected as instructed in previous Starter Solenoid Circuit Test, proceed as follows: Connect 1. Digital voltmeter set on low scale across large terminals of magnetic switch. Battery voltage will show immediately. Test 1. Push starter button with key on. Voltage will read zero. 2. Turn on and adjust carbon pile to 100 amp load (60 amp if 24-volt system). 3. Read and record voltage (V11) across magnetic switch on voltmeter, then release starter button. 4. Magnetic switch contactor voltage loss (V11) shall not exceed 0.2 volts for 12- or 24-volt system. 5. Replace magnetic switch if contactor voltage loss is excessive. DP-1024 CARBON PILE SECOND WIRE LOSS (10) CONTACTOR LOSS (11) FIRST WIRE LOSS (9) FIGURE 3-6. Solenoid Circuit Wiring and Contactor Test 3-17. TEST COMPLETION. Turn carbon pile off. Remove carbon pile and voltmeter from circuit. Leave solenoid S wire disconnected and temporarily taped for insulation at the terminal. 3-18. MAGNETIC SWITCH CIRCUIT TEST This test must be performed using full voltage of the system. If a 24-volt system was temporarily connected to a 12-volt system for a previous test, proceed to the Alternator Wiring Test, paragraph 3-26. Then, return to this test after the batteries have been reconnected to the 24-volt system. Note that the lead to the S terminal on the starter solenoid remains disconnected from previous tests (See Figure 3-7). Made with FlippingBook RkJQdWJsaXNoZXIy MTEyNjY3NA== 03DelcoRemy Diagnostic Manual130004222020 delcoremy.com Page 17 3-19. TEST PROCEDURE. NOTE Magnetic switch that does not close or drops out too soon can be caused by high resistance or open circuit in the control circuit. NOTE Leave the S lead disconnected to prevent engine from cranking during these tests. Connect 1. Digital voltmeter set on battery voltage scale to two small terminals on magnetic switch. If magnetic switch has only one small terminal, use switch bracket for other connection. Test 1. With key on, push start button. Listen for click that signifies magnetic switch closing. Note and record voltmeter reading V(13). 2. If magnetic switch closed (click detected or voltage at both large switch terminals) and voltage V(13) is within 1.0 volt (2.0 volts for 24-volt system) of battery voltage V(12), this circuit is okay. 3. If magnetic switch does not close and voltage V(13) is within 1.0 volt (2.0 volt for 24-volt system) of battery voltage V(12), replace magnetic switch and retest. 4. If voltage V(13) is more than 1.0 volt (2.0 volt for 24-volt system) below battery voltage, move the voltmeter lead on the magnetic switch ground to frame or motor ground terminal. With key on, push start button and read voltage V(14). If voltage V(14) is within 1.0 volt (2.0 volts for 24-volt system) of battery voltage, repair magnetic switch ground lead or connections. If not, replace voltmeter ground lead at magnetic switch ground terminal. 5. Repeat step 4, moving voltmeter plus lead to the following locations and measuring the specified voltages with the key on and the push-button depressed. If any voltage is not within 1.0 volt (2.0 volts for 24-volt system) of battery voltage, repair or replace the wire or component specified and retest: V(15)-wire between push-button and magnetic switch V(16) push-button V(17) wire between push-button and key switch V(18) key switch V(19) wire between key switch and solenoid BAT terminal 3-20. TEST COMPLETION. Remove voltmeter from vehicle. If all tests have been completed satisfactorily, reconnect lead to S terminal on starter solenoid so that engine can be started. PUSH BUTTON MAGNETIC SWITCH VOLTAGE (13) V(15) V(16) IGNITION BATTERY CABLE VOLTAGE (12) V(19) V(14) V(17) V(18) DP-1025 FIGURE 3-7. Magnetic Switch Circuit Test 3-21. STARTER REPLACEMENT DETERMINATION Up to this point, the batteries and starter wiring have been checked. The following additional checks should be made before considering starter replacement, and finally, the criteria for starter replacement, if necessary. 3-22. COLD WEATHER CRANKING. Starter circuits with a magnetic switch also can fail to hold during cold weather starting and low voltage, even though the switches and circuits tested okay at higher temperatures. This condition will sound as though the starter is failing to stay engaged with the engine. It is caused by the cold weather low voltage of the system releasing the electrical connection of the magnetic switch. To test for this condition, proceed as follows: Test CAUTION Large terminal studs on magnetic switch are at battery voltage. Engine should crank when jumper is connected. 1. With key switch on, press start button and have assistant clamp heavy battery jumper cable between two large studs on magnetic switch. Engine should crank. 2. Immediately remove jumper to stop engine cranking. 3. If engine starts with jumper in place, replace magnetic switch. Made with FlippingBook RkJQdWJsaXNoZXIy MTEyNjY3NA== 03DelcoRemy Diagnostic Manual130004222020 Page 18 4. If vehicle now starts properly, make sure starter mounting bolts are tight and proceed to Alternator Wiring Test. 3-23. AVAILABLE CRANKING VOLTAGE . If batteries, switches and wiring have been checked and starter still cranks slowly, check for available voltage at the starter while cranking. Proceed as follows: Test 1. Have assistant press push-button with key switch on while measuring voltage across solenoid BAT terminal and starter ground terminal. 2. If voltage is 9.0 volts (18 volts for 24-volt system) or less while cranking, check battery interconnecting cables as specified in next step. 3. Measure voltage across each battery while cranking. Touch voltmeter leads to terminals of every battery. If difference between any two battery readings in same box is more than 0.5 volt, or if any cable or connection feels warm to the touch, check or replace interconnecting cable(s) as required. 3-24. RING GEAR AND PINION CHECK. One final check before replacing the starter is to inspect the pinion and ring gear. Inspect 1. Pinion and ring gear visually while assistant bars engine over. Be sure to check entire ring gear. 2. If pinion is damaged, replace starter. If ring gear is damaged, replace ring gear and note that there is a likelihood the pinion also may be damaged. 3-25. STARTER REPLACEMENT. After making all tests specified, if the vehicle does not crank properly, the problem is with the starter or engine. Replace the starter and re-check to see if engine cranks properly. If not, then look for a mechanical problem with the engine. 3-26. ALTERNATOR WIRING TEST This procedure is the first step in checking out the charging system: output of the alternator, batteries and accessory loads with a minimum of voltage loss. Any loss slows the rate of charge to the batteries and could cause the batteries to be partially discharged. Discharged batteries can result in starter damage. Low output voltage can cause improper performance of other vehicle electrical components. 3-27. TEST PROCEDURE (See Figure 3-8). Instead of using the alternator output, this test uses the same current but draws it from the batteries. Using a carbon pile load, current flows in reverse through the circuit with the engine off. Proceed as follows: NOTE 24-volt systems must be connected to a temporary 12-volt configuration as described for Battery Cable Test, paragraph 3-8. NOTE Before proceeding with this test, make sure that the batteries have been tested and that the terminal has been cleaned and tightened. CAUTION Alternator output terminal is at battery voltage. Engine must be off for this test. Connect 1. Carbon pile to alternator output terminal and to ground. NOTE Jumper wires may be used to extend voltmeter leads if necessary. 2. Digital voltmeter set on low scale from alternator output terminal to positive battery terminal. Test 1. Turn on and adjust carbon pile to alternator-rated amperage output. 2. Read voltmeter and record voltage (V24), which is positive circuit voltage loss. Immediately turn off carbon pile. Connect 1. Digital voltmeter set on low scale from alternator ground to negative battery terminal. Test 1. Turn on and adjust carbon pile to alternator rated amperage output. 2. Read voltmeter and record voltage (V25), which is negative circuit voltage loss. Immediately turn off carbon pile. 3. Add positive circuit loss (V24) and negative circuit loss (V25) to get total system loss (V23). This loss (V23) shall not exceed: ⢠12-volt system - 0.500 volt maximum voltage loss ⢠24-volt system - 1.000 volt maximum voltage loss 4. Replace cables or repair circuits with excessive voltage loss. Made with FlippingBook RkJQdWJsaXNoZXIy MTEyNjY3NA== 03DelcoRemy Diagnostic Manual130004222020 delcoremy.com Page 19 3-28. TEST COMPLETION. Remove carbon pile and voltmeter. For 12-volt systems, proceed with Alternator Replacement Determination. For 24-volt systems, proceed as follows: 1. Reconnect temporary 12-volt system back to 24-volt system. 2. If Magnetic Switch Circuit Test was delayed, conduct at this time. 3. After completing Magnetic Switch Circuit Test, be sure to reconnect lead to S starter solenoid terminal. Then proceed with Alternator Replacement Determination. NEGATIVE CIRCUIT LOSS (25) CARBON PILE POSITIVE CIRCUIT LOSS (24) DP-1026 FIGURE3-8. AlternatorWiring Test - Typical 12-Volt System 3-29. ALTERNATOR REPLACEMENT DETERMINATION If the alternator wiring circuits are okay, conduct the following tests to determine if the alternator must be replaced. NOTE Make sure that alternator mounting hardware is secure and that belts are OK before testing alternator. NOTE Batteries must be satisfactorily load tested and near full charge with more than 12.4 volts â no load voltage. 3-30. ALTERNATOR VOLTAGE OUTPUT TEST. Conduct this test at shop temperature (See Figure 3-9). Connect 1. Digital voltmeter from positive alternator terminal to alternator ground. Test 1. Start engine and make sure all vehicle electrical loads are turned off. Fast idle engine until voltage stabilizes (does not increase) for two minutes. 2. Check that alternator output voltage does not exceed 15.5 volts (31 volts for 24-volt system). Remove voltmeter. NEGATIVE CIRCUIT LOSS (25) CARBON PILE POSITIVE CIRCUIT LOSS (24) DP-1026 FIGURE3-8. AlternatorWiring Test - Typical 12-Volt System 3-31. ALTERNATOR AMPERAGE OUTPUT TEST. Conduct this test at shop temperature (See Figure3-10). Connect 1. Carbon pile across the vehicle batteries hooked in parallel. 2. Induction ammeter clamped around alternator output wire. Made with FlippingBook RkJQdWJsaXNoZXIy MTEyNjY3NA== 03DelcoRemy Diagnostic Manual130004222020 Page 20 NOTE If more than one wire is connected to the alternator output terminal, clamp around ALL these wires. Test NOTE In the following test, alternator should be turning at approximate rated speed. Most heavy duty alternators are rated at 5000 rpm. Check manufacturerâs specifications for specific alternator being tested. 1. If off, start engine and make sure all vehicle electrical loads are turned off. Speed up engine. Turn on and adjust carbon pile until ammeter reads its highest value. Record this reading. 2. Turn off carbon pile and engine. 3. If reading is zero (no output), magnetize the rotor with the alternator hooked up normally. Momentarily connect a jumper lead from the battery positive (+) to the alternator relay (R) or indicator (I) terminal. This procedure applies to both negative and positive ground systems and will restore the normal residual magnetism. 4. Repeat steps 1 and 2. If output is still zero, replace the alternator. 3-32. ALTERNATOR REPLACEMENT. Replace alternator if either of the following conditions exist: 1. Alternator output voltage exceeds 15.5 volts (paragraph 3-30). If alternator has separate regulator, use the appropriate regulator service bulletin to isolate the defect. 2. Alternator output current is not within 10% of alternator rated output (stamped on alternator case). Examples: 30-SI - 105 amps, 26-SI - 85 amps, and 21-SI - 100 amps. 3-33. COMPLETION OF ALL TESTS Make sure that all test instruments have been removed from the vehicle and that the vehicle wiring, if altered, has been returned to the operational state. DP-1028 CARBON PILE FIGURE 3-10. Amperage Output Test Made with FlippingBook RkJQdWJsaXNoZXIy MTEyNjY3NA== 03DelcoRemy Diagnostic Manual130004222020 delcoremy.com Page 21 As the diagnostic procedures in this manual become part of your routine preventative maintenance program, here are two key tips to remember: 1. Donât jump to early conclusions. 2. Perform the diagnostic procedures in the exact order listed. These diagnostic procedures, if followed correctly, will enable you to diagnose issues and maintain heavy duty electrical systems so that they will perform well. However, the manual may not cover all the variables that you may encounter. If you need assistance, contact BorgWarner Technical Support at 800.372.0222 or email drts@borgwarner.com . S E C T I O N I V Summary Made with FlippingBook RkJQdWJsaXNoZXIy MTEyNjY3NA== 03DelcoRemy Diagnostic Manual130004222020 Page 22 S E C T I O N V Appendix 5-1. Smart IMS or SIMS Diagnostic Steps The Smart Starter with integrated magnetic switch (IMS) relay and integrated over crank protection (IOCP) is designed to protect the vehicle system from multiple system-related failures. The Smart Starter will accomplish this by not allowing the starter system to function in detrimental conditions to the starter or electrical system. To troubleshoot, you must first verify that the vehicle is equipped with the Smart Starter SIMS relay and integrated OCP. The SIMS relay is programmed to protect the vehicle from these failure modes: ⢠Starter engagement monitor/auto start retry â click no crank or prolong power ⢠Running engine lockout â engagement into running engine ⢠System low/high voltage lockout â over crank and pinion chatter ⢠Time limited crank â over crank ⢠Auto disengage at engine start â extended overrun ⢠Integrated OCP thermal cutout switch â heat damage from extended crank VISUAL DIFFERENCES STANDARD IMS RELAY SIMS RELAY When troubleshooting a vehicle system equipped with SIMS/IOCP, voltage and temperature are critical during diagnosis: ENGAGEMENT MONITOR/AUTO RETRY â 12-VOLT SYSTEM: The system will attempt to engage the pinion three times in less than one second. After three failed attempts, cycle the engine ignition off/on before making another crank attempt. LOW VOLTAGE LOCKOUT â 12-VOLT SYSTEM: Start attempts are not allowed if open circuit voltage is less than 12 volts (equal to 25% of the batteryâs state of charge). Check system voltage and charge batteries if this condition is present before removing starter. HIGH VOLTAGE LOCKOUT â 12-VOLT SYSTEM: If starter sees system voltage of greater than 14 volts, the SIMS/ IOCP will lock out, preventing the start attempt. This protects against high voltage jumpstarts (starter will be locked out if attempting jumpstarts above 14 volts). INTEGRATED OVER CRANK PROTECTION â 12-VOLT SYSTEM: If the starter is continuously cranked and reaches an internal temperature greater than 150ËC, the OCP switch will open and abort the start attempt. This allows the starter to cool down and the OCP to close so that the crank cycle can be performed. Allow the starter to cool before removing from the vehicle. Note: When troubleshooting the starting system, verify that there is suitable voltage at the âSâ terminal before removing the starter. The SIMS unit may be protecting the starting system if voltages are either high or low, or if over-cranking occurs and the OCP switch opens due to high temperatures. CAUTION LABEL Caution label to be placed on can of SIMS unit CAUTION â SMART STARTER! SMART IMSWITH IOCP EQUIPPED (INTEGRATED OVER CRANK) PREVENTS CRANKING UNDER LOW/HIGH VOLTAGE AND HIGH TEMPERATURE CONDITIONS Made with FlippingBook RkJQdWJsaXNoZXIy MTEyNjY3NA== 03DelcoRemy Diagnostic Manual130004222020 delcoremy.com Page 23 5-2. OVERCRANK PROTECTION (OCP) CIRCUIT CHECK To check the thermostat in the OCP circuit for continuity, detach wiring harness connector and connect an ohmmeter to the two thermostat terminals on the starter. The ohmmeter should read zero. If not, thermostat is open circuit and the starter should be replaced prior to proceeding with other tests in this booklet. DO NOT check thermostat when hot since it is supposed to be open circuit above certain temperatures. 5-3. MULTI-BATTERY CHARGING WITH SERIES AND PARALLEL CHARGERS These procedures assist in providing charged batteries for future service. However, âboostâ charging or âfastâ charging is not covered. Below are basic guidelines for charging groups of batteries and supplements information contained in the Delco Service Bulletins, 1B-115 and 1B-116. The two types of battery chargers in use today for charging a group of batteries are: ⢠Current-limiting (often called Constant â Current or Series Chargers) ⢠Voltage-limiting (often called Constant â Voltage or Parallel Chargers) With current-limiting, the batteries are connected so that each battery receives the same amount of charging current. (See Fig. 1 for typical hook-up.) With voltage-limiting, the batteries are connected so that the charging current is divided and each battery receives only the charging current it can accept at the chargerâs voltage. (See Fig. 2 for typical hook-up.) Because of these differences, the charging procedures also differ. No matter which type of charger is used, differences exist among batteries: age, capacity, size, state of charge, and type. These differences mean that time and attention must be given to batteries during the group-charging process. CHARGER A V V V V TEST VOLTMETER DP-1030 A CHARGER AMMETER FIGURE 1. A V V TEST VOLTMETER DP-1031 A CHARGER AMMETER FIGURE 2. Connect to same ground point as standard circuit (may be through relay or fuel pressure switch) Thermostat Leads (2) Motor Thermostat Connections DP-1029 DELCO REMY STARTERSWITH OVERCRANK PROTECTION Made with FlippingBook RkJQdWJsaXNoZXIy MTEyNjY3NA== 03DelcoRemy Diagnostic Manual130004222020 Page 24 To prevent undercharging or overcharging and battery damage on the charging rack, the following procedures are recommended: NOTE The following recommendations are for batteries with electrolyte and plates at room temperatures of 55Ë to 85ËF (13Ë to 30ËC). Extremely cold batteries accept very little charging current and will not conform to the suggested procedures. 5-4. GROUP CHARGING ON CURRENT-LIMITING OR SERIES CHARGERS 1. Visually inspect all batteries for cracked covers or cases; replace obviously damaged batteries. a. Filler-cap batteries: Check with hydrometer. If reading is 1.230 or more, test as outlined in Delco Service Bulletin 1B-115. If reading is below 1.230, proceed with charging procedure. If fluid level is low, add water to bring level sufficiently high for hydrometer readings, (but not to the split ring), then proceed with charging. After charging, add water just to split ring. b. Freedom batteries: Check built-in hydrometer; if clear or yellow, replace the battery. If hydrometer has a green dot, do not charge, but test as outlined in Delco Service Bulletin 1B- 116. If hydrometer is dark, proceed with charging procedure. 2. Connect batteries to charger as shown in Figure 1. Do not exceed the chargerâs voltage capabilities by connecting too many batteries. Make sure all connections are clean and tight. Set charging rate within 5-10 ampere range and maintain this charging rate throughout the charging procedure. 3. After two or three hours of charging, check batteries as follows: a. Filler-cap batteries: Take hydrometer readings at hourly intervals. Correct readings to 80ËF (27ËC). Remove any battery from charge when there is no increase in specific gravity after three successive hourly readings. Any battery that becomes hot (125ËF, 52ËC) or violently gasses, should be removed from the charger for testing. Readjust control to maintain the same charging rate after the batteries are removed. b. Freedom batteries: Check for green dot indication. Shake or tilt batteries at hourly intervals to see if green dot will stay visible. Also check terminal voltage of each battery with test voltmeter connected, as shown in Figure 1. While on charge, if voltage across the battery is 16.0 volts or more, or if the green dot appears, remove battery from charger. Any battery that becomes hot (125ËF, 52ËC), as determined by touching and feeling the case, or any battery that violently gasses, should be removed from the charger for testing. Readjust control to maintain the same charging rate on remaining batteries as charged batteries are removed. 4. After charging, all batteries should be tested as described in the testing procedure in Delco Service Bulletins 1B-115 and 1B-116 to make sure batteries are usable. 5-5. GROUP CHARGING ON VOLTAGE-LIMITING OR PARALLEL CHARGERS 1. Visually inspect all batteries for cracked covers or cases; replace obviously damagedbatteries. a. Filler-cap batteries: Check with hydrometer; if reading is 1.230 or more, test as outlined in Delco Service Bulletin 1B-115. If reading is below 1.230, proceed with charging procedure. If fluid level is low, add water to bring level sufficiently high for hydrometer readings, but not to split ring, then proceed with charging. After charging, add water to split ring. b. Freedom batteries: Check built-in hydrometer; if clear or yellow, replace battery. If hydrometer has a green dot, do not charge, but test as outlined in Service Bulletin 1B-116. If hydrometer is dark, proceed with charging procedure. 2. Connect batteries and test voltmeter to charger as shown in Figure 2. Make sure that all connections are clean and tight. Set charging voltage setting to a setting that does not exceed 16.0 volts. The charger may not be able to reach this voltage initially, but as batteries become charged and accept less current, the voltage will rise. The ammeter of the charger is indicating the total current flow to the connected batteries. This current divides into the various batteries. It is not a measure of each batteryâs current acceptance. Do not exceed the chargerâs capabilities by connecting too many batteries. Follow the charger manufacturerâs directions. 3. After two or three hours, check batteries at hourly intervals as follows: a. Filler-cap batteries: Take hydrometer readings at hourly intervals. Correct readings to 80ËF (27ËC). Remove any battery from the charge when there is no increase in specific gravity after three successive hourly readings. Any battery that becomes hot (125ËF, 52ËC) or violently gasses should be removed from the charger and tested. In the event that a hot battery is removed, most of the charging current was going to that battery and it will be necessary to continue charging the remaining batteries since they received very little charging current. b. Freedom batteries: Check for green dot indication. Remove from charger when green dot stays visible. Any battery that becomes hot (125ËF, 52Ëc), as determined by touching and feeling the case, or violently gasses, should be removed from the charger and tested. In the event that a hot battery is removed, most of the charging current was going to that battery and it will be necessary to continue charging the remaining batteries, since they received very little charging current. Readjust control to keep voltage below 16.0 volts, if necessary, as batteries are removed. 4. After charging, all batteries should be tested as described in the testing procedure in Delco Service Bulletins 1B-115 and 1B-116 to make sure batteries are usable. Made with FlippingBook RkJQdWJsaXNoZXIy MTEyNjY3NA== 03DelcoRemy Diagnostic Manual130004222020 delcoremy.com Page 25 5-6. HEAVY DUTY DIAGNOSTIC PROCEDURES DATA Section 3-7 BATTERY CABLE TEST W/500 AMP LOAD (FROM FIGURE 3-3) Section 3-15 and 3-16 STARTER SOLENOID CIRCUIT TEST W/100 AMP LOAD (FROM FIGURE 3-6) Section 3-27 ALTERNATOR WIRING LOSS AMP LOAD = ALTERNATOR RATED OUTPUT (FROM FIGURE 3-8) (AMP LOAD AND MAXIMUM VOLTAGE LOSSES SHOWN ARE FOR 12-VOLT SYSTEMS.) Delco Remy is a registered trademark of General Motors Corporation licensed to BorgWarner PDS (Anderson) L.L.C. POSITIVE CABLE LOSS _______________________________ NEGATIVE CABLE LOSS _______________________________ NEGATIVE CABLE LOSS _______________________________ V4 V5 (MAX. 0.500 V) FIRST WIRE LOSS ______________________ SECOND WIRE LOSS ______________________ MAG SWITCH LOSS ______________________ TOTAL SOLENOID CIRCUIT LOSS ______________________ V4 V10 V11 (MAX. 1.00 V) POSITIVE CIRCUIT LOSS _______________________________ NEGATIVE CIRCUIT LOSS _______________________________ ALTERNATOR CIRCUIT LOSS _______________________________ V24 V25 (MAX. 0.500 V) + + + + + + = Made with FlippingBook RkJQdWJsaXNoZXIy MTEyNjY3NA== 03DelcoRemy Diagnostic Manual130004222020 Page 26 NOTES __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ Made with FlippingBook RkJQdWJsaXNoZXIy MTEyNjY3NA== 03DelcoRemy Diagnostic Manual130004222020 delcoremy.com Page 27 NOTES __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________ Made with FlippingBook RkJQdWJsaXNoZXIy MTEyNjY3NA==